OIL BURNER

[YLP] Proportioning Oil Burner

BrochureHandling Manual

Characteristics

The proportion of oil and air can be regulated by the operation of a single lever. Stable combustion can be obtained easily. Therefore, controlling the atmospheric temperature in the furnace is easy. It is the most suited for the automatic combustion control system.

Specifications / Shape dimension

Specifications

Fuel Kerosene、Light Oil(YLP-L)、Oil(YLP-H)
Standard Pressure Oil 50kPa、 70kPa (YLP-6 only)
Air 6kPa
Accessories Butterfly Damper
Strainer
Reducing Valve
Pressure Gauge
Stop Valve
Front
Tile
Support
Shutter
Type Capacity
kW (×1,000kcal/h)
Air Flow Rate
(Nm3/h)
Connection
Air Oil
YLP-1 65(56) 60 Rc 1 1/2 Rc 3/8
YLP-2 108(93) 102 Rc 2
YLP-3 194(167) 180 Rc 2 1/2
YLP-4 367(316) 342 Rc 3 Rc 1/2
YLP-5 541(465) 498 Rc 4
YLP-6 649(558) 600
YLP-7 1,081(930) 1,020 125A(JIS5K)
YLP-8 1,622(1,395) 1,500 150A(JIS5K)

※ YLP-7、8 are flanged for connection to the air.

Dimension


Type A B C D E F G H J K L M N Mass
(kg)
YLP-1 541 222 161 71 17 300 270 230 212 166 564 4 15 47
YLP-2 581 252 166 76 220 48
YLP-3 634 272 190 82 350 320 250 243 62
YLP-4 782 312 251 101 19 440 410 350 300 216 574 116
YLP-5 866 357 278 114 23 500 460 400 316 19 172
YLP-6
YLP-7 1,132 450 337 171 19 600 540 500 335 318 676 8 21 329
YLP-8 1,274 520 394 186 660 600 560 375 448

Download of DXF data

※ Download procedure

  1. Put the cursor on the model designation of the outline drawing you want to download, and click the right button of the mouse.
  2. Select “Save Target As (A)” on the menu.
  3. Select a location to save, and click “Save.”
    ※ Some security software does not permit downloading. If that happens, set the securities to “OFF” before downloading.

Construction drawing

1 Oil Nozzle 11 Oil Valve Body 21 Seal Packing
2 Atomizer 12 Plug 22 Oil Flow Scale
3 Burner Body 13 Spindle Holder Spring 23 Proportioning Interlock
4 Screw Lead 14 Oil Control Spindle 24 Control Joint
5 Guide Screw 15 Seal Holder 25 Inner-Bladed Washer
6 Plug 16 O-Ring 26 Packing
7 O-Ring 17 Oil Control Handle
8 Operating Bush 18 Fixed Washer
9 Air Control Handle 19 Fixed Butterfly Nut
10 Flange 20 Taper Pin

Flow sheet

Flame Pattern YLP-LW (Long Flame Type)

Condition
In the Air
Air Pressure 6kPa
Fuel Kerosene
Type ØD (mm) L (mm) L1 (mm)
YLP-1LW 70 400 222
YLP-2LW 150 650 252
YLP-3LW 200 800 272
YLP-4LW 250 1,000 312
YLP-5LW 300 1,300 357
YLP-6LW 300 1,500 357

※There are difference of burner types depending on fuel used, YLP-H(Heavy Oil), YLP-L(Light Oil, Kerosene).
※YLP-W is long flame type.

Technical data

Flame temperature distribution

Flame temperature distribution
Burner YLP-1LW
Capacity 65kW
Fuel Kerosene
Air Pressure 6kPa
Measure R Thermocouple

MODEL TYPE SEARCH

TOP