Characteristics
As this burner tiles are set on the wall in the furnace, this burner can heat burner tile and the wall in the furnace circularly. This radiant heat can be used for heating the materials. This burner is used for oil only.
Specifications / Shape dimension
Specifications
Fuel | Kerosene、Light Oil |
Standard Pressure | Oil 50kPa Air 6kPa Atomizing Air 13 kPa |
Accessories | Regulating Cock |
Type | Capacity kW (×1,000kcal/h) |
Air Flow Rate(Nm3/h) | Connection | |||
Air | Atomizing Air |
Air | Atomizing Air |
Oil | ||
NOF-1F | 58(50) | 60 | 3.1 | Rc 1 1/2 | Rc 1/2 | Rc 3/8 |
NOF-2F | 116(100) | 120 | 5.4 | Rc 2 | ||
NOF-3F | 233(200) | 240 | 11.5 | Rc 2 1/2 | Rc 3/4 | |
NOF-4F | 350(300) | 360 | 16 | Rc 3 | ||
NOF-5F | 580(500) | 600 | 30 | 100A(JIS5K) |
Dimension
Type | A | B | C | D | E | F | G | H | J |
NOF-1F | 553 | 148 | 142 | 101 | 99 | 63 | 32 | 35 | 141 |
NOF-2F | 146 | ||||||||
NOF-3F | 693 | 205 | 175 | 138 | 112 | 55 | 180 | ||
NOF-4F | 182 | ||||||||
NOF-5F | 790 | 235 | 217 | 158 | 117 | 60 | 168 | ||
Type | K | L | M | N | P | Q(G) | Mass(kg) |
NOF-1F | 250 | 17 | 350 | 320 | 15 | 3/4 | 44 |
NOF-2F | |||||||
NOF-3F | 350 | 20 | 450 | 410 | 19 | 96 | |
NOF-4F | |||||||
NOF-5F | 400 | 500 | 460 | 1 | 132 |
Download of DXF data
※ Download procedure
- Put the cursor on the model designation of the outline drawing you want to download, and click the right button of the mouse.
- Select “Save Target As (A)” on the menu.
- Select a location to save, and click “Save.”
※ Some security software does not permit downloading. If that happens, set the securities to “OFF” before downloading.
Flame Pattern
Condition | |
In the Air | |
Air Pressure | 6kPa |
Fuel | Kerosene |
Excess Air Ratio | 1.1 |
Type | ØD (mm) | L (mm) | L1 (mm) |
NOF-1F | 300 | 60 | 160 |
NOF-2F | 450 | 80 | 160 |
NOF-3F | 600 | 90 | 220 |
NOF-4F | 650 | 110 | 220 |
NOF-5F | 700 | 150 | 250 |