Characteristics
This is a pilot gas burner for which you can use mixed gas. The pilot burner head length can be selected freely. You can use this burner for a wide range of usage.
Specifications / Shape dimension
Standard Pressure | Gas: 2.8kPa Air:4kPa |
Accessories | Transformer Cord Solenoid Valve Spark Plug Air Cock Gas Cock plug cap |
※Size L : Specified by customer
Type | Capacity kW (×1,000kcal/h) |
Connection Installation |
φA (mm) |
JP-20 | 3.4(2.9) | R 3/4 | 21.7 |
JP-25 | 5.2(4.5) | R 1 | 27.2 |
Download of DXF data
※ Download procedure
- Put the cursor on the model designation of the outline drawing you want to download, and click the right button of the mouse.
- Select “Save Target As (A)” on the menu.
- Select a location to save, and click “Save.”
※ Some security software does not permit downloading. If that happens, set the securities to “OFF” before downloading.