Characteristics
The simple clamp mechanism makes maintenance of the burner nozzle or burner tile easy.
Specifications / Shape dimension
Specifications
Fuel | Fuel Gases |
Standard Pressure | Gas:2~10kPa Air:6kPa |
Type | Capacity kW (×1,000kcal/h) |
Air Flow Rate (Nm3/h) |
Connection | |
Air | Gas | |||
IP-1FR | 58(50) | 60 | 40A(JIS5K) | RC 3/4 |
IP-2FR | 116(100) | 120 | ||
IP-3FR | 174(150) | 180 | 65A(JIS5K) | |
IP-4FR | 233(200) | 240 | ||
IP-5FR | 290(250) | 300 | 80A(JIS5K) | RC 1 |
IP-6FR | 350(300) | 360 | ||
IP-7FR | 465(400) | 480 | RC 1 1/2 | |
IP-8FR | 580(500) | 600 | 100A(JIS5K) | |
IP-9FR | 700(600) | 720 |
Dimension
Type | A | B | C | D | E | F | G | H | J | K | L | M (G) | Mass (kg) |
IP-1FR | 386 | 160 | 130 | 96 | 157 | Ø200 | 100 | 20 | 240 | 210 | 15 | 3/4 | 30 |
IP-2FR | |||||||||||||
IP-3FR | 407 | 180 | 97 | 169 | Ø250 | 120 | 320 | 280 | 48 | ||||
IP-4FR | |||||||||||||
IP-5FR | 476 | 210 | 170 | 96 | 199 | Ø320 | 150 | 24 | 390 | 350 | 21 | 73 | |
IP-6FR | |||||||||||||
IP-7FR | |||||||||||||
IP-8FR | 506 | 180 | 106 | 221 | Ø340 | 170 | 410 | 370 | 1 | 86 | |||
IP-9FR |
※ In placing an order for round tiles,affix “R” to the end of the model No.(Ex.IP-1FR)
※ IP are flange for connection to the air.
Download of DXF data
※ Download procedure
- Put the cursor on the model designation of the outline drawing you want to download, and click the right button of the mouse.
- Select “Save Target As (A)” on the menu.
- Select a location to save, and click “Save.”
※ Some security software does not permit downloading. If that happens, set the securities to “OFF” before downloading.
Flame Pattern
Condition | |
In the Air | |
Air Pressure | 6kPa |
Fuel | LPG |
Excess Air Ratio | 1.1 |
Type | ØD (mm) | L (mm) | L1 (mm) |
IP-1FR | 160 | 800 | 160 |
IP-2FR | 200 | 900 | 160 |
IP-3FR | 250 | 1,100 | 180 |
IP-4FR | 250 | 1,200 | 180 |
IP-5FR | 300 | 1,300 | 210 |
IP-6FR | 350 | 1,300 | 210 |
IP-7FR | 350 | 1,400 | 210 |
IP-8FR | 400 | 1,700 | 210 |