Characteristics
Combustion can be controlled proportionally only by operating the air butterfly damper. This premixing type gas burner in applied to many kinds of industrial furnaces and ceramic furnaces.
Specifications / Shape dimension
Specifications
Fuel | Fuel Gases |
Standard Pressure | Gas:2.8kPa Air:6kPa |
Accessories | Zero governor Butterfly Damper Gas valve Pressure Gauge |
Type | Capacity kW (×1,000kcal/h) |
Connection | |
Air | Gas | ||
HLGB-1 | 72(62) | Rc 1 1/2 | Rc 3/4 |
HLGB-2 | 130(112) | Rc 2 | 1 |
HLGB-3 | 276(238) | Rc 3 | Rc 1 1/4 |
HLGB-4 | 517(445) | Rc 4 | Rc 1 1/2 |
Dimension
Type | A | B | C | D | E | F | G | H | J | Mass (kg) |
||||
A□ | Rφ | A□ | Rφ | A□ | Rφ | |||||||||
HLGB-1 | 566 | 105 | 461 | 495 | 190 | 215 | 165 | 190 | 140 | 160 | 12 | 12 | 16 | |
HLGB-2 | 675 | 130 | 545 | 602 | 230 | 260 | 200 | 230 | 170 | 190 | 14 | 27 | ||
HLGB-3 | 896 | 170 | 726 | 748 | 285 | 320 | 250 | 285 | 215 | 245 | 15 | 16 | 48 | |
HLGB-4 | 1,125 | 220 | 905 | 859 | 350 | 395 | 310 | 350 | 270 | 305 | 18 | 89 |
※ In placing an order for square tiles,affix “A” to the end of the model No.(Ex.HLGB-1A)
※ In placing an order for round tiles,affix “R” to the end of the model No.(Ex.HLGB-1R)
Download of DXF data
※ Download procedure
- Put the cursor on the model designation of the outline drawing you want to download, and click the right button of the mouse.
- Select “Save Target As (A)” on the menu.
- Select a location to save, and click “Save.”
※ Some security software does not permit downloading. If that happens, set the securities to “OFF” before downloading.
Flame Pattern
Condition | |
In the Air | |
Air Pressure | 6kPa |
Fuel | LPG |
Excess Air Ratio | 1.1 |
Type | ØD (mm) | L (mm) | L1 (mm) |
HLGB-1 | 150 | 350 | 105 |
HLGB-2 | 200 | 520 | 130 |
HLGB-3 | 250 | 680 | 170 |
HLGB-4 | 330 | 980 | 220 |