GAS BURNER

[CJ] Ceramic Jet Gas Burner

Catalog 1
Instruction manual

Fuel

This is direct-ignition gas burner of nozzle mixed type using a light, compact ceramic combustion cylinder. Using no burner tiles, this gas burner can be easily installed to a furnace body and maintained with no difficulties. Flames are stirred by high-speed combustion gas at 130m/sec within the furnace. This ensures the uniform distribution of the temperature within the furnace. This burner can also be used for 300℃ hot air. This has widened the application of this burner to various heat treatment furnaces, heating furnaces, etc.

Specifications / Shape dimension

Specifications

Fuel Fuel Gases
Standard Pressure Gas:3~10kPa
Air:6kPa
Flame Safeguard System UV Phototube
Type Capacity
kW (×1,000kcal/h)
Air Flow Rate
(Nm3/h)
Connection
Air Gas
CJ-1 58(50) 75 Rc 1-1/2 Rc 1/2
CJ-2 140(120) 170 Rc 2 Rc 3/4
CJ-3 233(200) 300 Rc 2-1/2 Rc 1
CJ-4 372(320) 415 Rc 3 Rc 1-1/2

Dimension

Type A B C D E F G H J K Mass
(kg)
CJ-1 476 250 102 95 60 φ200 172 69 146 24 16
CJ-2 55 154
CJ-3 577 300 125 120 83 φ240 206 65 179 26
CJ-4 564 285 124 117 91 □220 □190 181 23 29

Download of DXF data

※ Download procedure

  1. Put the cursor on the model designation of the outline drawing you want to download, and click the right button of the mouse.
  2. Select “Save Target As (A)” on the menu.
  3. Select a location to save, and click “Save.”
    ※ Some security software does not permit downloading. If that happens, set the securities to “OFF” before downloading.

Flame Pattern

Condition
In the Air
Air Pressure 6kPa
Fuel LPG
Excess Air Ratio 1.1
Type L1 (mm) L (mm) ØD (mm)
CJ-1 250 500 100
CJ-2 250 600 150
CJ-3 300 700 180
CJ-4 285 800 220

MODEL TYPE SEARCH