OIL BURNER

[NOF-F] Flat Flame Oil Burner (Flange Type)

Catalog

Characteristics

As this burner tiles are set on the wall in the furnace, this burner can heat burner tile and the wall in the furnace circularly. This radiant heat can be used for heating the materials. This burner is used for oil only.

Specifications / Shape dimension

Specifications

Fuel Kerosene、Light Oil
Standard Pressure Oil 50kPa
Air 6kPa
Atomizing Air 13 kPa
Accessories Regulating Cock
Type Capacity kW
(×1,000kcal/h)
Air Flow Rate(Nm3/h) Connection
Air Atomizing
Air
Air Atomizing
Air
Oil
NOF-1F 58(50) 60 3.1 Rc 1 1/2 Rc 1/2 Rc 3/8
NOF-2F 116(100) 120 5.4 Rc 2
NOF-3F 233(200) 240 11.5 Rc 2 1/2 Rc 3/4
NOF-4F 350(300) 360 16 Rc 3
NOF-5F 580(500) 600 30 100A(JIS5K)

Dimension

Type A B C D E F G H J
NOF-1F 553 148 142 101 99 63 32 35 141
NOF-2F 146
NOF-3F 693 205 175 138 112 55 180
NOF-4F 182
NOF-5F 790 235 217 158 117 60 168
Type K L M N P Q(G) Mass(kg)
NOF-1F 250 17 350 320 15 3/4 44
NOF-2F
NOF-3F 350 20 450 410 19 96
NOF-4F
NOF-5F 400 500 460 1 132

Download of DXF data

※ Download procedure

  1. Put the cursor on the model designation of the outline drawing you want to download, and click the right button of the mouse.
  2. Select “Save Target As (A)” on the menu.
  3. Select a location to save, and click “Save.”
    ※ Some security software does not permit downloading. If that happens, set the securities to “OFF” before downloading.

Flame Pattern

Condition
In the Air
Air Pressure 6kPa
Fuel Kerosene
Excess Air Ratio 1.1
Type ØD (mm) L (mm) L1 (mm)
NOF-1F 300 60 160
NOF-2F 450 80 160
NOF-3F 600 90 220
NOF-4F 650 110 220
NOF-5F 700 150 250

MODEL TYPE SEARCH