Characteristics
It can mix fluid is the furnace by injecting the combustion gas at high speed, 40-60m/sec, and this keeps the temperature distribution uniform. High turndown ratio.
Specifications / Shape dimension
Specifications
Fuel | Kerosene、Light Oil、A.Oil |
Standard Pressure | Oil 50kPa Air 6kPa Atomizing Air 20 kPa |
Accessories | Regulating Cock |
Type | Capacity kW (×1,000kcal/h) |
Air Flow Rate(Nm3/h) | Connection | |||
Air | Atomizing Air |
Air | Atomizing Air |
Oil | ||
SOL-1 | 116(100) | 111 | 13 | Rc 1 1/2 | Rc 1/2 | Rc 3/8 |
SOL-2 | 209(180) | 198 | 23 | Rc 2 | ||
SOL-3 | 372(320) | 353 | 41 | Rc 3 | Rc 1 | |
SOL-4 | 580(500) | 551 | 64 | Rc 4 |
Dimension
Type | A | B | C | D | E | F | G | H | J | K | L | M | N | P | Q (G) |
R (G) |
Mass (kg) |
SOL-1 | 534 | 210 | 90 | 80 | 154 | 12 | 261 | 45 | 32 | 65 | 160 | 190 | 220 | 12 | 3/4 | 1/2 | 21 |
SOL-2 | 574 | 235 | 100 | 85 | 276 | 70 | 180 | 210 | 240 | 28 | |||||||
SOL-3 | 729 | 300 | 140 | 125 | 164 | 14 | 366 | 60 | 95 | 230 | 265 | 300 | 15 | 1 | 3/4 | 57 | |
SOL-4 | 809 | 350 | 160 | 135 | 16 | 396 | 110 | 270 | 310 | 350 | 19 | 100 |
Download of DXF data
※ Download procedure
- Put the cursor on the model designation of the outline drawing you want to download, and click the right button of the mouse.
- Select “Save Target As (A)” on the menu.
- Select a location to save, and click “Save.”
※ Some security software does not permit downloading. If that happens, set the securities to “OFF” before downloading.
Flame Pattern
Condition | |
In the Air | |
Air Pressure | 6kPa |
Fuel | Kerosene |
Excess Air Ratio | 1.1 |
Type | ØD (mm) | L (mm) | L1 (mm) |
SOL-1 | 100 | 550 | 210 |
SOL-2 | 120 | 700 | 235 |
SOL-3 | 160 | 900 | 300 |
SOL-4 | 210 | 1,150 | 350 |