RADIANT TUBE BURNER

[WRT] Wide Range Radiant Tube Burner

Catalog

Characteristics

This is a radiant tube burner having a large turn-down ratio (max. 1:40). This radiant tube burner is composed mainly of a main burner and a coaxial sub-burner. For the initial ignition, direct ignition featured by low-fire start is adopted. The main burner is ignited, then the sub-burner is ignited by the main burner flame, and then the sub-burner maintains constant combustion. For high-temperature applications, a heat exchanger can be installed to further energy saving.

Specifications / Shape dimension

Specifications

Fuel Fuel Gases
Standard Pressure Gas:2~10kPa
Air:6kPa
Flame Safeguard System UV Phototube
Type Capacity kW (×1,000kcal/h) Tube Connection
Main Burner Sub Burner Main Air Main Gas Sub Air Sub Gas
WRT-100 35(30) 2.3(2.0) 100A Rc 1 1/2 Rc 1/2 Rc 3/8 Rc 1/4
WRT-125 58(50) 125A Rc 2 Rc 3/4
WRT-150 93(80) 150A Rc 2 1/2 Rc 1

Dimension

Type A B C D E F G H J K L M N
WRT-100 116 100 55 38 127 20 30 55 149 80 165 250~450(STEP50) 436
WRT-125 90 40 169 100 200 410
WRT-150 150 138 72 53 179 125 230 525

Download of DXF data

※ Download procedure

  1. Put the cursor on the model designation of the outline drawing you want to download, and click the right button of the mouse.
  2. Select “Save Target As (A)” on the menu.
  3. Select a location to save, and click “Save.”
    ※ Some security software does not permit downloading. If that happens, set the securities to “OFF” before downloading.

Flow sheet

Technical data

Condition
Burner WRT-100
Recuperator RL-100
Air temperature 330℃
Excess Air Ratio 1.2
Furnace temperature 950℃
Capacity Tube temperature(℃) Difference of Tube Maximum temperature(℃)
(kW ) 1 2 3 4 5 6 7
40 1,030 995 1,020 1,000 985 935 965 95
20 1,035 1,005 1,015 995 990 960 975 75
8 960 940 950 935 935 915 930 45

MODEL TYPE SEARCH

TOP