Characteristics
This burner has a built-in heat exchanger to utilize exhaust heat for preheating combustion air. Owing to its unique heat exchanging method, this burner has realized a high energy-saving effect. Also, owing to its direct ignition method, this burner has realized the turn-down ratio up to 1:5. Furthermore, this burner is free from ignition failure in the ON-OFF operation. This burner can also be used for indirect heating and direct heating.
Specifications / Shape dimension
Fuel |
Fuel Gases |
Standard Pressure |
Gas 10kPa、Air 6kPa |
Flame Safeguard System |
UV Phototube |
Type |
Capacity
kW
(×103 kcal/h) |
Main Air Flow Rate
m3/h |
Connection |
Main |
Gas |
Exhaust |
REC-10 |
100(8.6) |
114 |
JIS5K 50A |
Rc 1 |
JIS5K 80A |
REC-20 |
200(17.2) |
228 |
JIS5K 65A |
Rc 1 |
JIS5K 100A |
Type |
A |
B |
C |
D |
E |
F |
G |
H |
J |
K |
L |
M |
REC-10 |
989 |
350 |
639 |
300 |
524 |
453 |
280 |
19 |
325 |
80 |
217 |
65 |
REC-20 |
989 |
350 |
639 |
300 |
530 |
453 |
260 |
20 |
320 |
116 |
320 |
65 |
Type |
N |
P |
Q |
R |
S |
T |
U |
Mass
(kg) |
REC-10 |
19 |
320 |
8-φ23-PCD280 |
200 |
190 |
390 |
22.5° |
85 |
REC-20 |
23 |
430 |
12-φ23-PCD390 |
247 |
245 |
492 |
15° |
120 |
Download of DXF data
※ Download procedure
- Put the cursor on the model designation of the outline drawing you want to download, and click the right button of the mouse.
- Select “Save Target As (A)” on the menu.
- Select a location to save, and click “Save.”
※ Some security software does not permit downloading. If that happens, set the securities to “OFF” before downloading.
Flow sheet
Flame Pattern
Condition |
Air Pressure |
6kPa |
Fuel |
13A |
Furnace Pressure |
0.3kPa |
形式 |
φD mm |
L mm |
REC-10 |
150 |
800 |
REC-20 |
200 |
1100 |
Technical data
Temperature characteristics for furnace temperature
Temperature characteristics for furnace temperature |
Condition |
Burner |
REC-10 |
Capacity |
100kW |
Fuel |
13A |
Excess Air Ratio |
1.1 |