Characteristics
Out mixing type burner which sprays the oil by high-pressure air or vapor. Simple construction and handing. Available in 2 type : a natural draft type for combustion with primary air only and a force draft type combined with the secondary air casting. Please use the MR-type micro regulating cock for the primary air (vapor) and oil regulating valve.
Specifications / Shape dimension
Fuel | Kerosene、Light Oil、Oil |
Forced draft type secondary air pressure | 0.2~2kPa |
※ Dimension L is 75mm as a standard. This dimension may by changed to your order.
Type | Capacity kW(×1,000kcal/h) |
Vapor | Air | ||
Pressure kPa(kg/cm2) |
Amount of consumption (kg/h ) |
Pressure kPa(kg/cm2) |
Amount of consumption (Nm3/min) |
||
HP-304 | 163(140) | 200(2) | 3.5 | 200(2) | 0.08 |
HP-308 | 326(280) | 7 | 0.16 | ||
HP-315 | 651(560) | 300(3) | 14 | 300(3) | 0.3 |
HP-330 | 1,302(1,120) | 28 | 0.6 | ||
HP-345 | 1,942(1,670) | 42 | 0.9 | ||
HP-355 | 2,593(2,230) | 400(4) | 56 | 400(4) | 1.2 |
HP-375 | 3,244(2,790) | 70 | 1.5 | ||
HP-395 | 4,105(3,530) | 88 | 1.9 |
Type | Oil pressrure(kPa) | Connection | Mass(kg) | |
Air or vapor | Oil | |||
HP-304 | 50 | Rc 1/2 | Rc 3/8 | 2.5 |
HP-308 | ||||
HP-315 | ||||
HP-330 | ||||
HP-345 | ||||
HP-355 | ||||
HP-375 | ||||
HP-395 |
Download of DXF data
※ Download procedure
- Put the cursor on the model designation of the outline drawing you want to download, and click the right button of the mouse.
- Select “Save Target As (A)” on the menu.
- Select a location to save, and click “Save.”
※ Some security software does not permit downloading. If that happens, set the securities to “OFF” before downloading.