Specifications
| Fuel | Fuel Gases |
| Standard Pressure | Gas:3~10kPa Air:6kPa |
| Type | Capacity kW (×1,000kcal/h) |
Air Flow Rate (Nm3/h) |
Connection | |
| Air | Gas | |||
| SFG-1F | 58(50) | 60 | Rc 1 1/2 | Rc 1 |
| SFG-2F | 116(100) | 120 | Rc 2 | |
| SFG-3F | 233(200) | 240 | Rc 2 1/2 | Rc 1 1/2 |
| SFG-4F | 350(300) | 360 | Rc 3 | |
| SFG-5F | 580(500) | 600 | 100A(JIS5K) | Rc 2 |
Dimension

| Type | A | B | C | D | E | F | G | H | J | K | L | M(G) | Mass (kg) |
| SFG-1F | 431 | 148 | 142 | 101 | 17 | 250 | 141 | 81 | 350 | 320 | 15 | 3/4 | 38 |
| SFG-2F | 146 | 39 | |||||||||||
| SFG-3F | 574 | 205 | 175 | 138 | 20 | 350 | 180 | 102 | 450 | 410 | 19 | 86 | |
| SFG-4F | 182 | ||||||||||||
| SFG-5F | 664 | 235 | 217 | 150 | 400 | 168 | 80 | 500 | 460 | 1 | 128 |
Download of DXF data
※ Download procedure
- Put the cursor on the model designation of the outline drawing you want to download, and click the right button of the mouse.
- Select “Save Target As (A)” on the menu.
- Select a location to save, and click “Save.”
※ Some security software does not permit downloading. If that happens, set the securities to “OFF” before downloading.
Flame Pattern

| Condition | |
| In the Air | |
| Air Pressure | 6kPa |
| Fuel | LPG |
| Excess Air Ratio | 1.1 |
| Type | ØD (mm) | L (mm) | L1 (mm) |
| SFG-1F | 200 | 250 | 160 |
| SFG-2F | 250 | 300 | 160 |
| SFG-3F | 300 | 350 | 220 |
| SFG-4F | 350 | 500 | 220 |
| SFG-5F | 500 | 600 | 250 |