GAS BURNER

[NGF] Flat Flame Gas Burner

Catalog

Characteristics

Direct mounting type-fitting the burner tile to the furnace wall. The burner heats the tile and furnace wall circularly. Therefore the emitted heat warms up the materials.

Specifications / Shape dimension

Specifications

Fuel Fuel Gases
Standard Pressure Gas:2~10kPa
Air:6kPa
Type Capacity
kW (×1,000kcal/h)
Air Flow Rate
(Nm3/h)
Connection
Air Gas
NGF-1 58(50) 60 Rc 1 1/2 Rc 1
NGF-2 116(100) 120 RC 2
NGF-3 233(200) 240 Rc 2 1/2 Rc 1 1/2
NGF-4 350(300) 340 RC 3
NGF-5 580(500) 600 100A(JIS5K) Rc 2

Dimension

Type A B C D E F G H J K
(G)
Mass(kg)
NGF-1 431 160 130 101 81 141 250 220 M12 3/4 42
NGF-2 146
NGF-3 574 220 160 138 102 180 350 310 M16 94
NGF-4 182
NGF-5 664 250 202 150 80 168 400 360 1 128

※ NGF-5 are flanged for connection to the air.

Download of DXF data

※ Download procedure

  1. Put the cursor on the model designation of the outline drawing you want to download, and click the right button of the mouse.
  2. Select “Save Target As (A)” on the menu.
  3. Select a location to save, and click “Save.”
    ※ Some security software does not permit downloading. If that happens, set the securities to “OFF” before downloading.

Flame Pattern

Condition
In the Air
Air Pressure 6kPa
Fuel LPG
Excess Air Ratio 1.1
Type ØD (mm) L (mm) L1 (mm)
NGF-1 350 70 160
NGF-2 500 80 160
NGF-3 650 80 220
NGF-4 750 100 220
NGF-5 800 150 250