OIL BURNER

[SFO-F] Spot Flame Oil Burner (Flange Type)

Catalog

Characteristics

Adjacent heating is possible because the flame is wide and short. This is a burner heating material centrally by radiation of the flame.

Specifications / Shape dimension

Specifications

Fuel Kerosene、Light Oil
Standard Pressure Oil 50kPa
Air 6kPa
Atomizing Air 13 kPa
Accessories Regulating Cock
Type Capacity
kW (×1,000kcal/h)
Air Flow Rate(Nm3/h) Connection
Air Atomizing
Air
Air Atomizing
Air
Oil
SFO-1F 58(50) 60 3.1 Rc 1 1/2 Rc 1/2 Rc 3/8
SFO-2F 116(100) 120 5.4 Rc 2
SFO-3F 233(200) 240 11.5 Rc 2 1/2 Rc 3/4
SFO-4F 350(300) 360 16.0 Rc 3
SFO-5F 580(500) 600 30.0 100A(JIS5K)

Dimension

Type A B C D E F G H J
SFO-1F 553 148 142 101 99 63 32 35 141
SFO-2F 146
SFO-3F 693 205 175 138 112 55 180
SFO-4F 182
SFO-5F 790 235 217 158 117 60 168
Type K L M N P Q(G) Mass(kg)
SFO-1F 250 17 350 320 15 3/4 42
SFO-2F
SFO-3F 350 20 450 410 19 87
SFO-4F
SFO-5F 400 500 460 1 129

Download of DXF data

※ Download procedure

  1. Put the cursor on the model designation of the outline drawing you want to download, and click the right button of the mouse.
  2. Select “Save Target As (A)” on the menu.
  3. Select a location to save, and click “Save.”
    ※ Some security software does not permit downloading. If that happens, set the securities to “OFF” before downloading.

Flame Pattern

Condition
In the Air
Air Pressure 6kPa
Fuel Kerosene
Excess Air Ratio 1.1
Type ØD (mm) L (mm) L1 (mm)
SFO-1F 180 150 160
SFO-2F 200 200 160
SFO-3F 350 350 220
SFO-4F 450 400 220
SFO-5F 550 500 250