PILOT BURNER

[PBX] Pilot Gas Burner

Catalog

Characteristics

The ceramic lining inside the burner prevents its heat from red-heating. You can detect flame easily by the flame rod method or photo-cell method.

Specifications / Shape dimension

Specifications

Standard Pressure Gas:2.8kPa
Air:4kPa
Accessories Transformer
Cord with plug cap(PK-B-C 2m)
Solenoid Valve(100V or 200V)
Air Cock
Gas Cock
Spark Plug
Small Valve(SV-10)
Sight Hole

※ Please give us the information of the fuel you are using, the voltage of the accessorial solenoid valve and the flame detection method.

Type Capacity
kW (×1,000kcal/h)
Connection
Air Gas Installation
PBX-2 3.4(2.9) Rc 1/2 Rc 3/8 3/4
PBX-3 6.5(5.6) Rc 3/4 R 1

Dimension

Type A B C D E F G H J K L M Mass(kg)
PBX-2 74 208 125 83 25 269 144 200 91 112 5.5 55 6.7
PBX-3 77 249 148 101 34 292 211 94 121 7.4

Download of DXF data

※ Download procedure

  1. Put the cursor on the model designation of the outline drawing you want to download, and click the right button of the mouse.
  2. Select “Save Target As (A)” on the menu.
  3. Select a location to save, and click “Save.”
    ※ Some security software does not permit downloading. If that happens, set the securities to “OFF” before downloading.

Flame detection

1)Ultra-Vision method

Ultra-Vision method: For the Ultra-Vision method, remove the looking glass located at the back of the burner (See next figure). Mount the spark plug on the side with no countersinking, and male sure of the right side. The other side with countersinking is for mounting the plug. If the spark plug is mounted on the wrong side, the Ultra-Vision will detect sparks from the spark plug and issue a wrong signal.

2)Flame rod method

Flame rod method: For the flame rod method, remove the plug from the side with the countersinking, and mount the flame rod(FL-3)there instead.

Technical data

  1. Capacity
  2. Flame length

1. Capacity

2. Flame length