Characteristics
The ceramic lining inside the burner prevents its heat from red-heating. You can detect flame easily by the flame rod method or photo-cell method.
Specifications / Shape dimension
Specifications
Standard Pressure | Gas:2.8kPa Air:4kPa |
Accessories | Transformer Cord with plug cap(PK-B-C 2m) Solenoid Valve(100V or 200V) Air Cock Gas Cock Spark Plug Small Valve(SV-10) Sight Hole |
※ Please give us the information of the fuel you are using, the voltage of the accessorial solenoid valve and the flame detection method.
Type | Capacity kW (×1,000kcal/h) |
Connection | ||
Air | Gas | Installation | ||
PBX-2 | 3.4(2.9) | Rc 1/2 | Rc 3/8 | R 3/4 |
PBX-3 | 6.5(5.6) | Rc 3/4 | R 1 |
Dimension
Type | A | B | C | D | E | F | G | H | J | K | L | M | Mass(kg) |
PBX-2 | 74 | 208 | 125 | 83 | 25 | 269 | 144 | 200 | 91 | 112 | 5.5 | 55 | 6.7 |
PBX-3 | 77 | 249 | 148 | 101 | 34 | 292 | 211 | 94 | 121 | 7.4 |
Download of DXF data
※ Download procedure
- Put the cursor on the model designation of the outline drawing you want to download, and click the right button of the mouse.
- Select “Save Target As (A)” on the menu.
- Select a location to save, and click “Save.”
※ Some security software does not permit downloading. If that happens, set the securities to “OFF” before downloading.
Flame detection
1)Ultra-Vision method
Ultra-Vision method: For the Ultra-Vision method, remove the looking glass located at the back of the burner (See next figure). Mount the spark plug on the side with no countersinking, and male sure of the right side. The other side with countersinking is for mounting the plug. If the spark plug is mounted on the wrong side, the Ultra-Vision will detect sparks from the spark plug and issue a wrong signal.
2)Flame rod method
Flame rod method: For the flame rod method, remove the plug from the side with the countersinking, and mount the flame rod(FL-3)there instead.