Characteristics
This requires no air piping, and is compact, so it is available for small air heating furnaces, heat treating furnaces and drying furnaces.
Specifications / Shape dimension
Capacity | 35kW (30,000kcal/h) |
Fuel | Fuel Gases |
Standard Pressure | Gas:3~10kPa Air:0.3kPa |
Flame Safeguard System | UV Phototube |
Type | Capacity kW (×1,000kcal/h) |
Air Flow Rate (Nm3/h) |
Mass (kg) |
MS-1 | 35(30) | 36 | 9 |
Download of DXF data
※ Download procedure
- Put the cursor on the model designation of the outline drawing you want to download, and click the right button of the mouse.
- Select “Save Target As (A)” on the menu.
- Select a location to save, and click “Save.”
※ Some security software does not permit downloading. If that happens, set the securities to “OFF” before downloading.
Flame Pattern
Condition | |
In the Air | |
Air Pressure | 0.3kPa |
Fuel | LPG |
Excess Air Ratio | 1.0 |
Type | ØD (mm) | L (mm) | L1 (mm) |
MS-1 | 100 | 600 | 106 |