Characteristics
This burner is a large-capacity nozzle mixed type burner. At a separated port, a stable flame can be gained. You can take as bet turndown rate by this burner.
Specifications / Shape dimension
Specifications
Fuel | Fuel Gases |
Standard Pressure | Gas:2~10kPa Air:5kPa |
Type | Capacity kW (×1,000kcal/h) |
Air Flow Rate (Nm3/h) |
Connection | |
Air | Gas | |||
MXG-200 | 2,300(2,000) | 2,400 | 200A(JIS5K) | Rc 2 1/2 |
MXG-300 | 3,500(3,000) | 3,600 | 250A(JIS5K) | Rc 3 |
MXG-400 | 4,600(4,000) | 4,800 | ||
MXG-500 | 5,800(5,000) | 6,000 | 300A(JIS5K) | Rc 4 |
MXG-600 | 7,000(6,000) | 7,200 |
Dimension
Type | A | B | C | D | E | F | G | H | J | K | L | M | N (G) |
P (G) |
Mass(kg) |
MXG-200 | 1,000 | 350 | 250 | 310 | 90 | 16 | 180 | 540 | 600 | 660 | 280 | 21 | 1 | 1 | 250 |
MXG-300 | |||||||||||||||
MXG-400 | |||||||||||||||
MXG-500 | 1,020 | 270 | 19 | 600 | 660 | 720 | 300 | 1 1/2 | 290 | ||||||
MXG-600 |
※ MXG are flanged for connection to the air.
Download of DXF data
※ Download procedure
- Put the cursor on the model designation of the outline drawing you want to download, and click the right button of the mouse.
- Select “Save Target As (A)” on the menu.
- Select a location to save, and click “Save.”
※ Some security software does not permit downloading. If that happens, set the securities to “OFF” before downloading.
Flame Pattern
Condition | |
In the Air | |
Air Pressure | 5kPa |
Fuel | LPG |
Excess Air Ratio | 1.1 |
Type | ØD (mm) | L (mm) | L1 (mm) |
MXG-200 | 900 | 2,700 | 350 |
MXG-300 | 1,000 | 3,200 | 350 |
MXG-400 | 1,000 | 3,500 | 350 |
MXG-500 | 1,200 | 4,000 | 350 |
MXG-600 | 1,300 | 4,500 | 350 |