Characteristics
Direct mounting type-fitting the burner tile to the furnace wall. The burner heats the tile and furnace wall circularly. Therefore the emitted heat warms up the materials.
Specifications / Shape dimension
Specifications
Fuel | Fuel Gases |
Standard Pressure | Gas:2~10kPa Air:6kPa |
Type | Capacity kW (×1,000kcal/h) |
Air Flow Rate (Nm3/h) |
Connection | |
Air | Gas | |||
NGF-1F | 58(50) | 60 | Rc 1 1/2 | Rc 1 |
NGF-2F | 116(100) | 120 | RC 2 | |
NGF-3F | 233(200) | 240 | Rc 2 1/2 | Rc 1 1/2 |
NGF-4F | 350(300) | 340 | RC 3 | |
NGF-5F | 580(500) | 600 | JIS5K 100A | Rc 2 |
Dimension
Type | A | B | C | D | E | F | G | H | J | K | L | M (G) |
Mass (kg) |
NGF-1F | 431 | 148 | 142 | 101 | 17 | 250 | 141 | 81 | 350 | 320 | 15 | 3/4 | 43 |
NGF-2F | 146 | ||||||||||||
NGF-3F | 574 | 205 | 175 | 138 | 20 | 350 | 180 | 102 | 450 | 410 | 19 | 96 | |
NGF-4F | 182 | 93 | |||||||||||
NGF-5F | 664 | 235 | 217 | 150 | 400 | 168 | 80 | 500 | 460 | 1 | 130 |
Download of DXF data
※ Download procedure
- Put the cursor on the model designation of the outline drawing you want to download, and click the right button of the mouse.
- Select “Save Target As (A)” on the menu.
- Select a location to save, and click “Save.”
※ Some security software does not permit downloading. If that happens, set the securities to “OFF” before downloading.
Flame Pattern
Condition | |
In the Air | |
Air Pressure | 6kPa |
Fuel | LPG |
Excess Air Ratio | 1.1 |
Type | ØD (mm) | L (mm) | L1 (mm) |
NGF-1F | 350 | 70 | 160 |
NGF-2F | 500 | 80 | 160 |
NGF-3F | 650 | 80 | 220 |
NGF-4F | 750 | 100 | 220 |
NGF-5F | 800 | 150 | 250 |